• Global Presence
  • Career
  • Employee Login
  • Contact Us
    • About Us
      • About The Company
      • Our Timeline
      • Core Values
      • Leadership
      • Director's Message
      • Global Footprint
      • R&D and Innovation
      • Quality
      • Core Technology
    • Products
      • Rapid Tests
        • ULTRA
          • Blood Borne
          • Vector Borne
          • Water Borne
          • Others
        • STANDARD Q
          • Respiratory
          • Others
          • Blood Borne
      • Fluorescent Immunoassay (FIA)
        • Analyzer
          • F 2400
          • F 200
          • d-BLOCK Incubator
        • Cardiovascular
          • TnI FIA
          • CK-MB FIA
          • hs-CRP
          • D-dimer FIA
          • NT-proBNP FIA
          • TnI/CK-MB Combo FIA
        • Hormone
          • TSH FIA
          • TSH II FIA
          • T3
          • T4
          • fT4
          • ?-hCG FIA
          • LH FIA
          • FSH FIA
          • Prolactin FIA
          • AMH FIA
        • Diabetes
          • HbA1c
          • U-Albumin FIA
        • Gastrointestinal
          • H.pylori Ag FIA
          • iFOB FIA
        • Vector-borne
          • Dengue NS1 Ag FIA
          • Dengue IgM/IgG FIA
          • Chikungunya IgM/IgG FIA
          • Tsutsugamushi IgM/IgG FIA
        • Respiratory
          • S. pneumoniae Ag FIA
          • Strep A Ag FIA
          • RSV Ag FIA
          • Legionella Ag FIA
        • Infection
          • CRP
          • PCT FIA
        • Bone Metabolism
        • Blood Borne
      • Molecular Diagnostics
        • Analyzer
          • STANDARD™ M10 Analyzer
        • Assay Menu
          • STANDARD M10
          • ULTRA M10
      • Hematology
        • Analyzer
        • Reagent
      • Blood Glucose Monitoring System
        • Cronic Care
          • Diabetes
            • GDH Enzyme
            • GOD Enzyme
            • CGMS
          • Blood Pressure Monitors
            • STANDARD BP Care
            • STANDARD BP Care Comfort
            • STANDARD BP Care Plus
          • Lancets
            • ULTRA Blood Lancets
            • ULTRA Safety Lancet
      • ELISA Kits
        • STANDARD E
          • TB Feron IGRA
        • ULTRA
          • Dengue NS1 ELISA
          • Dengue IgM Capture ELISA
          • Dengue IgG Capture ELISA
      • G6PD
        • STANDARD G6PD
    • Media Centre & News
      • Photo & Videos
      • Events
    • Investor Relations
      • Corporate Social Responsibility
      • Corporate Announcements
    • Support Centre
      • Sales Support
    Products

    STANDARD GlucoNavii® GDH

    STANDARD GlucoNavii® GDH

    Experience precision glucose monitoring in "Clinical Setup where Accuracy Matters Most" with GlucoNavii-GDH – an innovative diagnostic solution powered by advanced GDH-FAD enzyme technology with wide Sample ranges to ensure consistent and accurate glucose determination across all fresh blood sample types – capillary, venous, arterial & neonatal – meeting diverse clinical testing requirements with superior reliability.

    • Advanced 99.99% Pure Gold Electrode Technology- which ensures excellent product accuracy due to high conductivity of gold electrode.
    • Laser Patterning- it ensures better precessions hence repeatability of the test is excellent.
    • GDH-FAD Enzyme- it allows universal blood sampling (Capillary, Venous, Arterial, & Neonatal) due to high HCT Range & avoid various drug interference.
    • No Coding- it helps to avoid any result variation in case of CODE-CHIP replacement is not done with new vial of the strips for coding meters.
    • EN ISO 15197:2015 Compliant- it ensures the accuracy approval of the products in comparison to YSI

    Intended use:

    • STANDARD GlucoNavii® GDH
    • STANDARD GlucoNavii® GDH
    1 Enzyme GDH-FAD
    2 Assay Method Electrochemistry Method
    3 Sample Volume & Test Time 0.5 ?L & 5 Sec.
    4 HCT range 0%-70%
    5 Test Range 10-600 mg/dL
    6 Test Strip Shelf Life 24 Months
    7 Electrode 99.99% Pure Gold
    8 Coding No Coding
    9 Function Average calculation of 7, 14 and 30 day measurement results Before & After Meal option Hypoglycemia warning alarm system GlucoNavii DMS program for PC
    10 Sample Capillary,Venous Arteiral & Neonate Whole blood
    Type Catalogue No Product
    System 01GM30 STANDARD GlucoNavii GDH Blood Glucose Meter
    Strip RK050-100 STANDARD Gluco Navii GDH Blood Glucose Test Strip (2X50T)
    Control Solution (Option) 01GCS20 Control solution kit (2 Vials : M&H level)
    Get In Touch
    Contact Us @ Toll Free: 18001023105 care@sdbiosensor.co.in

    About Us

    • About The Company
    • Our Timeline
    • Core Values
    • Leadership
    • Director's Message
    • Global Footprint
    • R&D and Innovation
    • Quality
    • Core Technology

    Media Center

    • Photo Gallery
    • Video Gallery

    Insight & News

    • Events
    • Awards & Recogition

    Investor Relations

    • Corporate Social Responsibility
    • Corporate Announcements

    Support Center

    • Sales Support
    • General Enquiry Form
    Global Presence Career Employee Login Contact Us